Enter Custom Information Into Data Sets on a FieldLab Pressure Calibrator

Enter Custom Information Into Data Sets on a FieldLab Pressure Calibrator

Note: You may need to perform free updates to your FieldLab and FieldLab Desktop in order to use this feature.

Available for FieldLab Desktop versions 1.10.0 and newer, and FieldLab v1.117 and newer.

Update Firmware
Update FieldLab Desktop

Enter and save important information along with each Data Set by creating custom fields that you can edit directly on the FieldLab. For example: After you complete a test on the FieldLab, you can add the serial number of the device you tested, name of the technician who performed the work, work order number, etc.

Once saved, the information will be conveniently bundled alongside all the test data for future reference.

To use Custom Data Fields, they must first be added to the Test Mode. Learn how, here: Add Custom Data Fields to a Test Mode.

1

Perform the Test

On the FieldLab, activate a Test Mode with a Custom Data Field on the gauge and perform the test.

Learn how to Activate a Test Mode on your FieldLab Pressure Calibrator.

2

View and edit the Data Set

After the test is complete, view the Data Set containing the data from the test you just performed. You can view the custom fields you assigned to the Test Mode here. In this example the custom field label, Serial Number, is visible with a blank placeholder for the data to be entered. To add info to the custom data field, select Edit.

3

Select the Custom Data Field you wish to edit from the list.

4

Input the information using the on-screen keypad.

5

Select “OK” to save.

6

View the Custom Data Field

The information will be saved in the Data Set along with your test data. You can view the saved info in the Data Set on the FieldLab, on FieldLab Desktop (once the Data Set is imported), and in the Exported Data Set file.


    • Related Articles

    • Add Custom Data Fields to Data Sets

      How to add Custom Data Fields to allow more custom information to be added to a Data Set. Note: You may need to perform free updates to FieldLab Desktop in order to use this feature. Available for FieldLab Desktop versions 1.10.0 and newer. Update ...
    • Delete Data Sets from FieldLab Pressure Calibrator

      You can delete data sets from the FieldLab Pressure, and once they're imported, from the FieldLab Desktop application. 1 Go to the Menu List by pressing the Menu Button 2 Step down to the Data Sets list item with the Down Button and select Data Sets. ...
    • Import Data Sets from a FieldLab Digital Pressure Calibrator

      What you will need The FieldLab Desktop app installed on your PC. Free download. A FieldLab with data sets saved to it. USB cord to connect the FieldLab to your PC (included with purchase of FieldLab). 1. Power On the FieldLab. 2. Open the FieldLab ...
    • Quick-Start Guide and User Manual for the FieldLab Pressure Calibrator

      Download in PDF format below.
    • Calibrate the pressure sensor on a FieldLab

      Do-it-yourself instructions for calibrating a Ralston digital gauge with the free FieldLab Desktop software. At the end of this process, FieldLab Desktop will automatically make any necessary adjustments to bring your FieldLab to acceptable ...
    • Recent Articles

    • Pressure decay after squeezing hydraulic pump handles

      Pressure decay is a natural effect of using a hydraulic pump and does not necessarily (always check) mean a leak in your system. Here's why: When you use a hydraulic pump to increase system pressure rapidly, the hydraulic fluid's temperature rises. ...
    • How to Place an Order Using the Ralston Instruments Distributor Portal

      Purpose: This article explains how Ralston Instruments distributors can efficiently place an order using the Ralston Instruments Distributor Portal. Note that this is only available to users who are employees of authorized Ralston Instruments ...
    • How to Request a Quote from Ralston Instruments

      Overview At Ralston Instruments, we aim to make the quote request process as streamlined as possible for both end users and distributors. This guide outlines the steps for each group to request a quote efficiently. For End Users End users are ...
    • Calibrate the pressure sensor on a Field Gauge and Process Meter

      Do-it-yourself instructions for calibrating a Ralston digital gauge with the free FieldLab Desktop software. At the end of this process, FieldLab Desktop will automatically make any necessary adjustments to bring your Ralston gauge to acceptable ...
    • How long do the keypads on the LC gauge last?

      The keypad buttons on the LC10, LC20 and LC30 gauges last typically 5-10 million cycles. This varies depending on the ambient temperature as well as the force with which the buttons are pushed.