FieldLab Digital Pressure Calibrator
Battery Life
Battery Life of a FieldLab Digital Pressure Calibrator From a fully charged battery: Approximately 72 Hours with backlight on 2,016 Hours with display in sleep mode.
Find the Max Pressure of a FieldLab Digital Pressure Calibrator
Learn how to locate the max rated pressure for a FieldLab device. Exceeding the max rated pressure of your FieldLab could damage it and have an adverse affect on its functionality. Ralston Instrument offers FieldLab Pressure devices in a variety of ...
Guide to the External Features of a FieldLab Digital Pressure Calibrator - Back
Visual overview of the anatomy of the FieldLab Pressure Gauge. PRINT ARTICLE 1. USB Port 2. Power Port
Guide to the External Features of a FieldLab Digital Pressure Calibrator - Front
Anatomy of the FieldLab Pressure, front-side. Maximum Rated Pressure Power Button Log Button Menu Button Up Button Zero Button Backlight Button Left Button Zoom Button Right Button Down Button Pressure Port
Overview of the information on a FieldLab Pressure Calibrator screen
Anatomy of the FieldLab Pressure screen. Test Mode Name Data Logging in Progress Calibration Test In Progress Wireless Connection to FieldLab Desktop USB Connection to FieldLab Desktop Battery Charge Time Between Logging Pressure Points Highest ...
Log Pressure Data on a FieldLab Pressure Calibrator
Learn how to record pressure data with your FieldLab Pressure. To begin the process of recording pressure data, simply press the Log Button. The FieldLab will either begin recording pressure data immediately with a Data Logging Test Mode, or it will ...
Add Custom Data Fields to Data Sets
How to add Custom Data Fields to allow more custom information to be added to a Data Set. Note: You may need to perform free updates to FieldLab Desktop in order to use this feature. Available for FieldLab Desktop versions 1.10.0 and newer. Update ...
Enter Custom Information Into Data Sets on a FieldLab Pressure Calibrator
Note: You may need to perform free updates to your FieldLab and FieldLab Desktop in order to use this feature. Available for FieldLab Desktop versions 1.10.0 and newer, and FieldLab v1.117 and newer. Update Firmware Update FieldLab Desktop Enter and ...
Delete Data Sets from FieldLab Pressure Calibrator
You can delete data sets from the FieldLab Pressure, and once they're imported, from the FieldLab Desktop application. 1 Go to the Menu List by pressing the Menu Button 2 Step down to the Data Sets list item with the Down Button and select Data Sets. ...
Import Data Sets from a FieldLab Digital Pressure Calibrator
What you will need The FieldLab Desktop app installed on your PC. Free download. A FieldLab with data sets saved to it. USB cord to connect the FieldLab to your PC (included with purchase of FieldLab). 1. Power On the FieldLab. 2. Open the FieldLab ...
Activate a Test Mode on your FieldLab Pressure Calibrator
You can save up to 16 different Test Modes to your FieldLab Pressure. Learn how to locate and activate the Test Mode you need. Note: You can create and add new Test Modes to your FieldLab Pressure with FieldLab Desktop. Instructions for doing so are ...
Sync Tests between FieldLab Desktop and your FieldLab
Use FieldLab Desktop to sync Test Modes on your FieldLab devices. Test Modes are stored and managed in the Test Modes Library, which can be found in the FieldLab Desktop application (Free to download and use). Custom Test Modes can be added to ...
Add Test Modes to a FieldLab
Add custom tests to a FieldLab Pressure Calibrator from FieldLab Desktop App. Note that FieldLab will not allow you to add a Test Mode if it contains a maximum pressure that exceeds the FieldLab Pressure's max pressure specifications. FieldLab ...
Add Custom Data Fields to a Test
Note: You may need to perform free updates to your FieldLab and FieldLab Desktop in order to use this feature. Available for FieldLab Desktop versions 1.10.0 and newer, and FieldLab Pressure Calibrator firmware v1.117 and newer. Instructions for ...
Run a Snapshot Logging Test on a FieldLab
Log multiple single-pressure points and save them to one data set on an intrinsically safe Ralston FieldLab Pressure Calibrator. What you will need: A Ralston FieldLab Digital Pressure Calibrator with: A max pressure that will accommodate your ...
Use a FieldLab to Run a valve test with auto-detection of crack and reseat
Use this article if you selected "Auto Detection of Crack and Reseat" when you created your valve test in FieldLab Desktop. The FieldLab interface is slightly different if you created your test with "Manual Marking of Crack and Reseat". To learn how ...
Create and Edit a Valve Test for your FieldLab Digital Pressure Calibrator: Quick Overview
This article provides a quick overview. For more detailed, step-by-step instructions, see: Create a custom Pressure Safety Valve / Pressure Relief Valve Test for a FieldLab This features requires FieldLab Desktop 1.24.0 or later. You can update to ...
Create a custom Pressure Safety Valve / Pressure Relief Valve Test to run on a FieldLab
Create a new valve test and add it to a FieldLab Pressure Calibrator to perform tests on pressure safety and pressure relief valves. This feature requires: FieldLab Desktop App version 1.24.0 or later installed on your PC. You can update from within ...
Adjust settings for Auto Power Off for a FieldLab Pressure Calibrator while in Manual Mode
Use FieldLab Desktop to adjust the length of time before the FieldLab automatically Powers Off off to conserve battery life. Each Test Mode, including Manual Mode, has its own Auto Power Off settings. When you Activate a Test Mode on the FieldLab, ...
Adjust Auto Backlight Off on a FieldLab while in Manual Mode
Use FieldLab Desktop to control the amount of time that the backlight stays on before shutting off automatically to conserve battery life. Each Test Mode has its own Auto Backlight Off settings. When you Activate a Test Mode on the FieldLab, whatever ...
Adjust Auto Display Sleep: Manual Mode
Use FieldLab Desktop to adjust the length of time before the screen display turns off to conserve battery life while your FieldLab is in Manual Mode. Each Test Mode, including Manual Mode, has its own Auto Display Sleep settings. When you Activate a ...
Adjust Logging Interval in Manual Mode for a FieldLab Digital Pressure Calibrator
Use FieldLab Desktop to adjust the length of time between each point logged on a FieldLab while in Manual Mode. 1 Open FieldLab Desktop on your computer. 2 Plug the FieldLab into your computer with the provided USB Cord and Power it On. 3 On the ...
Run a Hydrostatic Test on a FieldLab
Use a FieldLab and one or more Field Gauges to perform a Hydrostatic Test. Overview This article will show you how to use a FieldLab and one or two Field Gauge LC20s to perform a Hydrostatic Test with one pressure reading and up to two separate ...
Enable High Speed Data Logging at 128 Times Per Second
Use a FieldLab Pressure Calibrator to log rapidly changing pressure at up to 128 times per second. Create a new or edit an existing Data Logging Test Mode Go to the Test Modes section of FieldLab Desktop and create a new Data Logging Test Mode, or ...
Log Exact Readings or Average Readings Over Interval
Feature Available for FieldLab Desktop versions 1.8.1 and newer, and FieldLab v1.117.003 and newer. 1 In the Test Modes section, under the Test Modes main heading, create a new Data Logging Test Mode. 2 Create the Test Mode, under the "Each Point is" ...
Adjust Settings for Auto Backlight on a FieldLab during a Data Logging Test
Use FieldLab Desktop to control the amount of time that the backlight stays on before shutting off automatically to conserve battery life. Each Test Mode has its own settings. When you Activate a Test Mode on the FieldLab, whatever the settings are ...
Change Display Sleep Timer on a FieldLab for a Data Logging Test
When you Activate a Test Mode on a FieldLab Digital Pressure Calibrator, the settings for that Test Mode will apply to the FieldLab as long as that Test Mode is active. Each Test Mode has its own Auto Display Sleep settings. You can use FieldLab ...
Data Logging Test Settings Overview
Introduction to the Data Logging Test Modes screen in FieldLab Desktop. Create and edit the custom Data Logging Test you need to run on a FieldLab Pressure Calibrator. Test Mode Name - Enter a custom name for your Test Mode. Test Mode Units - Select ...
Run a Calibration Test with a FieldLab Digital Pressure Calibrator
Use a FieldLab to test the accuracy of another device. Step-by-step text instructions below the video. You must first Create a Calibration Test and Add it to the FieldLab. For instructions, see: Create a New Calibration Test Mode Add Test Mode to a ...
Link a Ralston device to FieldLab Desktop
Manage settings and update firmware on a Field Gauge, FieldLab, or Process Meter by linking it to FieldLab Desktop software on your computer. 1. Download and install the latest version of FieldLab Desktop. You will need FieldLab Desktop version 1.24 ...
Run a Calibration Test on a FieldLab Pressure Calibrator
Use a FieldLab to test the accuracy of another device. Step-by-step instructions 1. Create a Calibration Test and Add it to the FieldLab. 2. Add your new Calibration Test to the FieldLab. 3. Make the proper connections. Make airtight connections ...
Quick-Start Guide and User Manual for the FieldLab Pressure Calibrator
Download in PDF format below.
Link to FieldLab Desktop
Link a Field Gauge, Process Meter, or FieldLab to FieldLab Desktop so you can manage setting, get the latest firmware updates, and log data directly to your computer from the Field Gauge. This article applies to Ralston Field Gauge LC10, LC20, ...